All boilers are designed and built in accordance with requirements of the ASME Boiler and Pressure Vessel Code

WNS Series Gas / Oil Hot Water Boiler

Capacity: 0.7 - 14 MW Pressure: 0.7 - 1.25 Mpa Learn More

SZS Series Gas / Oil Hot Water Boilers

Capacity: 7 - 116 MW Pressure: 1.0 - 1.6 Mpa Learn More

DZL Series Biomass Fired Steam Boilers

Capacity: 2 – 20 t/h Pressure: 1 - 2.5 Mpa Learn More

Model CB 15-100 HP Boilers - Complete Boiler Room Solutio

Model CB 15-100 HP Boilers A6-6 Rev. 07-10 BOILER HP 15C 20C 30C 40C 50 60 70 80 100 RATINGS - SEA LEVEL TO 3000 FT Rated Cap. (lbs steam/hr @212°F) Btu Output (1000 Btu/hr) 518 502 690 670

Boilers (industrial) Specifications | Engineering3

The boiler is powered by gas. Natural gas and propane are common types. Oil The boiler is powered by oil. Steam / Hydronic The boiler is fueled by steam or hot water. Waste Heat / Indirect Waste heat boilers are designed to burn waste or tail gasses to generate steam for process and/or power. Wood

China 6000 Kg/H Industrial Fire Tube Gas Oil Steam Boil

Gas Boiler, Steam Boiler, Boiler manufacturer / supplier in China, offering 6000 Kg/H Industrial Fire Tube Gas Oil Steam Boiler, 10t H City Gas Steam Generating Boiler Machine for Restaurant School, Low Emission Gas-Fired Wet Back Firetube Hot Water Boiler and so on.

Fuel & Electric Fuel & Electric Steam Boilers | Precisi

ST Electric Steam Boiler Capacities: 100 PPH to 10,000 PPH (10 BHP to 300 BHP) @ 99.5% efficiency Standard Model: ASME Section IV “H” Stamp (< 15 PSI) or Section I “S” Stamp (> 15psi) Compliances: UL Subject 834, NEC/NFPA Article 424-G, ASME Safety Code CSD-1 Despite its compact footprint, the Model ST’s large steam chest delivers high quality, dry steam with minimum carryover.

SAMPLE SPECIFICATION - Superior Boil

sample specification is normally used as the base template for the boiler specification. MODEL: SEMINOLE 70 ­ 1500 HP 1.0 Specification Overview 2.0 Structural Specifications 3.0 Connections 4.0 Boiler Trim 5.0 Factory Firetest SEMINOLE 3­Pass Steam Boiler, 70 ­ …

MOHICAN - Superior Boil

h i c a n S t e m p l f h t p: / s u e r i o b l. c m M a n % 2 0 S f 5 1.0 Specification Overview Top of Page 1.1 The boiler shall be a 4-pass Mohican wetback boiler manufactured by Superior Boiler Works. Model No. _____ . The boiler shall not have less than five square feet of A.S.M.E. heating surface, measured on the fireside, per rated

Boiler Formulas - Johnston Boil

Boiler Horsepower What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP = (LB/HR*fe)/34.5 BHP Boiler Horsepower BHP = (LB/HR*fe)/34.5 Lb/Hr Pounds per Hour BHP = 21500 * 1.08 / …

Hurst Boiler | Boiler Models| Plan Views | Spec Shee

File Size: 107KB Hurst boiler literature downloads, boiler models, plan views, manuals and spec sheets available for download. Available in 8 Models from 100 - 2000 BHP. Steam Pressures to 15-300 PSI. Hot Water Section I and Section IV. Euro Series Brochure 1.23 MB Serie Euro Esp. 1.4 MB Euro Series Steam Specifications 56.5 KB

Firebox Series: Low Pressure 15 PSI Ste

Firebox Series: Low Pressure 15 PSI Steam Capacities From: 27.5 to 100 BHP 1115 to 4247 MBTU/HR Rayes Boiler & Welding is the manufacturer of the innovative Firebox Series on average, uses 50% less fuel to create steam or hot water for any application needs, in half the amount of time when compared to traditional boilers. Firebox line

150 PSI High Pressure Steam Boilers Power Burner Fir

150 PSI High Pressure Steam Boilers Power Burner Fired RITE ENGINEERING & MFG. CORP. COMMERCE, CALIFORNIA 90040 PHONE (562) 862-2135 FAX (562) 861-9821 www.riteboiler.com Rev. 3/2014 PRODUCT DESCRIPTION

(PROJECT STANDARDS AND SPECIFICATION

2. The boiler and auxiliary equipment with the exception of the forced draft fans and drivers, shall be designed for a minimum of 10% excess air for firing gas fuel and 15% excess air for firing oil fuel or combination gas and oil fuel. 3. Steam drum internal are to include the steam collecting system and all